- All
- Product Management
- News
- Introduction
- Corporate Outlets
- FAQ
- Corporate Video
- Corporate Brochure
Product Center
Honesty and Pragmatism, Striving for Excellence, Pursuing Quality, and Providing Superior Service
Vortex flow meter
The stress-type vortex flowmeter is a type of velocity flowmeter, widely used in the petroleum, chemical, power, light industry, and power heating industries. Our company's vortex flowmeter production execution standards are Vortex Flow Sensor (JB/T9249-2015) and Verification Regulation Vortex Flowmeter (JJG1029-2007)
Keywords:
Category:
Other traffic products
Hotline:
Product Description
Main Features
■ No moving parts, long-term stability, simple structure, easy installation and maintenance;
■ The sensor output is a pulse frequency, which is linearly proportional to the actual flow rate of the measured fluid. It has zero drift and excellent stability. Various structural forms are available, including pipe-type and insertion-type flow sensors.
■ High accuracy: typically ±1.0% for liquids and ±1.5% for gases;
■ Wide measurement range, reaching 1:20 within a Reynolds number of 2×104~7×106;
■ Low pressure loss (approximately 1/4~1/2 of an orifice flow meter), an energy-saving flow meter;
■ Flexible installation methods. It can be installed horizontally, vertically, or at various angles depending on the on-site process pipeline;
■ Uses anti-interference circuits and anti-vibration sensor heads, with certain anti-environmental vibration performance.
■ Uses ultra-low power single-chip microcomputer technology. One 3V 10AH lithium battery can last for more than 5 years.
■ Software corrects the nonlinearity of the instrument coefficient to improve measurement accuracy.
■ Uses EEPROM to protect the cumulative flow from power failure, with protection time exceeding 10 years.
Main Technical Parameters
■ Measured medium: steam, compressed air, coal gas, liquids, and other high-velocity media
■ Implementation standard: Vortex flow sensor (JB/T9249-2015)
■ Flange connection: DN15-DN300; Clamp connection: DN15-DN300
■ Accuracy grade: Liquid: ±1%; Gas or steam: ±1.5%, ±1%
■ Range ratio: 1:10, 1:15, 1:20
■ Sensor material: 304 stainless steel; 316L stainless steel, etc.
■ Output: Pulse signal, 4~20mA signal
■ Communication: RS485 communication, HART protocol, etc.
■ Explosion-proof grade: ExdIICT6 Gb
Previous Page
Next Page
Previous Page
Next Page
Related Recommendations
Honesty and Pragmatism, Striving for Excellence, Pursuing Quality, and Providing Superior Service